    We are installing southwire royal DLO cable. Is this cable suitable for a submerged in water install? We are using the 535.3 size cable, what size lug do you recommend?

  • 0
    Avatar
    Jimmy Lu

    I want to get 50ft sample for Southwire SVT1802-0/105C,can you provide next Monday?it's very urgent.thanks!

  • 0
    Avatar
    Jeff Hartley

    24AWG 4 Pair Shielded Industrial Ethernet Cable

    We are using Cat 5e. CM. CMX. AWM Style 2463. 75°C. Sunlight Resistance. Outdoor Rated. RoHS-2 cable, however the cable wirers are slightly thicker than the standard cat5e cable this makes the RJ45 connecters very tight when feeding the wires into the connecter and is taking way to long to install.

    So what is the recommended RJ45 connecter to use with this cable that fits correctly?  

  • 0
    Avatar
    Al Slater

    What is the approximate impedance for Southwire 890559 and a pair of triad cable 890567?

    Al Slater

    Slatercom-WCD

  • 0
    Avatar
    Carlos Atkins

    Hello, I am tying to locate standard specifications for VFD cable. Application is for indoor use, roughly 50 horsepower VFD and motor. Could anyone help me out?

  • 0
    Avatar
    Kurt Cyr

    Morning.

    I am looking for the outside diameter for 3c2 G-GC cable

  • -1
    Avatar
    Wes Hobbs

    When is stock code assigned to non standard cables (Spec 46654) 1/0

     

  • 0
    Avatar
    BILL CLARK

    I AM TRYING TO SPECIFY 14AWG 600V TC-ER MULTI-CONDUCTOR (3,4,7,9,12,19,25 CONDUCTORS) THE CONDUCTORS NEED TO BE BLACK AND NUMBERED. I ALSO NEED A OVERALL SHIELD WITH DRAIN WIRE. A GROUND WIRE AND FOIL SHIELD ARE NOT REQUIRED. THE CABLE WILL BE USED WITH 24VDC DIGITAL INPUTS AND OUTPUTS. THE CABLES WILL BE ROUTED IN A COMMON CABLE TRAY WITH 4-20mADC CABLES

  • 0
    Avatar
    Sanjay Parikh

    am trying to  perform IR test  between  concetric neutral and ground   on  28KV concentric  neutral  LLDPE  jacketed cable  installed in the  PVC , concrete in case duct  and  getting result  all over the  place  from  Kilo Ohm  to Gohm . which is  correct ? what is  a  correct way to do it  . 

     

  • 0
    Avatar
    Rob Turner

    Is your #14 XHHW-2 cable 1000 volt rated?

  • 0
    Avatar
    CURTIS W. EATON

    I have a customer who need 100A at 250V single phase at the end of a 1395' pull.  He will be putting it in Poly Pipe and he want Aluminum wire.  What size of wire will he need?  And is there a cable in duct that is already designed for this that I can quote him?

  • 0
    Avatar
    David Parsons

    I need to know application for the G Mining Cable

    I want to use it to supply equipment on a mobile dock.. 

    If mounted on the side of floating dock does it need protection from damage?

    Can it be run in conduit if necessary to protect it?

  • 0
    Avatar
    Albert Gonzales

    I have a contractor installing #4/3c VFD Cable. My question is does your termination kit work also for a different brand that is not Southwire?

  • 0
    Avatar
    john.thompson

    I have a customer that removed the tape shield incorrectly back to the connector coming in the tap box. There is now about 5 feet of cable missing its shield for all 3 phases coming out of a 3C armor cables. 

     

    Can this tape shield be repaired in the field?

    Do they make a replacement type CU tape or shield?

     

  • 0
    Avatar
    rsmithsr

    I am bidding 2 jobs 12470v and don't know what size cable to use.

    1. 12470 high and 230v low 250kva 3-phase transformer. What size wire for the 12470v ?

    2.  12470v High and 230v low 1-phase 164 KVA transformers 3-ea. What size wire for the 12470v.

  • 0
    Avatar
    sitereach2

    I am interested in selecting a proper wire UL type for PVC schedule 40 run from solar panels to Inverter.  What is best types that you manufacture for this connection ?  (130 ft underground <3%)

  • 0
    Avatar
    Jeronimo

    Use of the cable E220129-H , is suitable for encoder?